LaserLiner CompactCube-Laser 3 Manual De Instrucciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
3
Slope mode
Do not release the transport restraint, set slide switch (3) to „OFF". Select
and switch on the laser with the selection button. Sloping planes can now
be measured. This mode cannot be used to perform horizontal or vertical
levelling as the laser lines are no longer aligned automatically. This is signalised
by the laser lines flashing.
LASER
Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with a line
of 2.5 m length on the wall, making sure that the bob can swing freely.
Switch on the device and align the vertical laser to the plumb line.
The precision is within the specified tolerance if the deviation between
the laser line and the plumb line is not greater than ± 2.5 mm.
Checking the horizontal line
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the
wall. Turn the laser cross approx. 2.5 m to the
right and mark point C. Check whether the
horizontal line from point C is level with point B
to within ± 2.5 mm. Repeat the process by turning
the laser to the left.
!
Regularly check the calibration before use, after transport
and after extended periods of storage.
LASER
LASER
CompactCube-Laser 3
LASER
B
2,5 m
C
11