4.
Important notes
• Installation, commissioning and maintenance are to be performed only by a
qualified expert in accordance with the provided instructions, legal requirements,
and the recognised engineering standards.
• All technical connection regulations specified by the local water and electricity
supply companies must be observed.
• The battery compartment with battery or power supply with extension cable must
be ordered separately (see Accessories,
• We reserve the right to make changes.
5.
Application
AQUACONTACT - DN 15 shower fitting for concealed mounting, with electronic
timer control using battery or mains power. For connection to premixed hot water or
cold water. For wall installation in switch box provided on site. 30 second flow time.
With integrated hygiene flush (24h after last actuation, for 10s). Functions which can
be activated via reflection code on sensor: Activation/deactivation of hygiene flush
and cleaning switch-off (3 min.).
Additional functions via optional remote control
– Setting the flow and interval times
– Switch from time control to body reflection, maximum flow time of 300 seconds
– Program-controlled thermal disinfection with safety switch-off
6.
Technical specifications
Minimum flow pressure:
Recommended flow pressure:
Maximum operating pressure:
Calculation of flow rate:
Volumetric flow:
Operating voltage:
Power consumption:
Protection class:
7.
Scope of delivery
8.
Dimensions
9.
Installation example
chapter
20).
1.0 bar
1-5 bar
10 bar
0.20 l/s
0.50 l/s at a flow pressure of 3 bar
6 VDC
1.5 W
IP 67
5