16. Adjusting the cleaning switch-off
You can activate the cleaning switch-off with the remote control (not part of the
scope of delivery, see Accessories,
Cleaning switch-off on the fitting
16.1 Hold your hand around 10 cm from the sensor for 3 seconds.
16.2 Between the 3rd and 5th flashing of the LED, remove your hand from the range of
the sensor.
• The LED does not flash.
16.3 After between 3 and 10 seconds, hold your hand around 10 cm from the sensor
again.
16.4 Once the LED has flashed three times, remove your hand from the range of the
sensor.
• The fitting will be switched off for 3 minutes.
• The LED flashes in a 10 second cycle.
☞
If you hold your hand around 10 cm from the sensor for at least 3 seconds, the fitting
will be reactivated before the 3 minutes has expired.
17. Maintenance and care
The fitting must be checked and maintained at regular intervals depending on the
water quality and in accordance with the local conditions, and rules and regulations
applicable at the site.
Maintain the following components:
• Filters (see
Use suitable cleaning agents which are not harmful to the fitting in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
18. Replacing a filter
Water volume regulator filter
18.1 Remove the cover plate (see
18.2 Unscrew the locking screws (a) on the water volume regulators.
18.3 Replace the filters (b).
☞
Important!
Note the installation position of the filters.
18.4 Reassemble in reverse order.
10
chapter
18.)
chapter
chapter
20) or directly on the fitting.
17.).