Nice M3BAR Instrucciones Y Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 81
Input led
Parameter Led (level)
L1
Time
L1
Pause
L2
L3
L4
L5
L6
L7
L8
L2
Function
L1
Step by
L2
step
L3
L4
L5
L6
L7
L8
L3
Speed
L1
Motor
L2
L3
L4
L5
L6
L7
L8
L4
1 LIGHT
L1
Output
L2
L3
L4
L5
L6
L7
L8
L5
Led Output
L1
(cover lights)
L2
L3
L4
L5
L6
L7
L8
L6
Motor
L1
force
L2
L3
L4
L5
L6
L7
L8
L7
Loop
L1
Detector
L2
Sensitivity
L3
L4
L5
L6
L7
L8
L8
Braking
L1
L2
L3
L4
L5
L6
L7
L8
– Do not set an excessively high value for the "motor force" as this may impair operation of the safety system or damage the pole;
– If the "Motor force control" is used in support of the system for impact force reduction, after each adjustment the force measurement procedure must be performed, as envisaged
by standard EN 12445 .
– Wear and atmospheric conditions influence movement of the pole; motor force settings should be checked periodically.
TABLE 8 - Second level functions
Value
3 seconds
5 seconds
7 seconds
10 seconds
15 seconds
20 seconds
40 seconds
60 seconds
Open – stop – close - stop
Open – stop – close - open
Open – close – open - close
Apartment block 1
Apartment block 2
Step by step 2
Hold-to-run
Opening in semi-automatic mode, closing in dead man mode
Speed 1 (50%)
Speed 2 (80%)
Speed 3 (100%)
Open V3, Close V1
Open V1, Close V2
Open V2, Close V3
Open V3, Close V2
Open V2, Close V1
Pole Open Indicator (24 V - 10 W)
Pole closed (24 V - 10 W)
Pole open (24 V - 10 W)
Flashing light(12 V - 21 W)
Flashing light 1 (24 V - 10 W) (for pole lights)
Electric lock(24 V - 10 W)
Suction cup(24 V - 10 W)
Maintenance indicator (24 V - 10 W)
Flashing light (only during the manoeuvre)
Flashing light 1 (always flashing)
Courtesy light
Always lit
Red traffic light
Green traffic light
One-way traffic light
Two-way traffic light
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force 8 (high)
100% - maximum
90%
80%
70%
60%
50%
40%
30% - minimum
0 - absent
1
2
3
5
6
8
9 - maximum
WARNINGS:
Description
Sets the pause time, i .e . the time that
passes between the end of an open-
ing manoeuvre and the start of an au-
tomatic closing manoeuvre
This parameter is only effective if the
"automatic Closure" is active .
Sets the sequence of commands as-
sociated with the input or the radio
control: "Step by step" .
Sets the motor speed during normal
travel .
Selects the type of device connected
to the LIGHT output .
Important! – If the programmed set-
ting is modified, check the type of
voltage of the new device connected
to the LIGHT terminal and ensure that
it corresponds to the type of voltage
of the selected programming level .
Select the operating mode of the de-
vice connected to the led output .
Modes from L1 to L4 can be asso-
ciated to the led flashing light device.
Modes from L5 to L8 can be associ-
ated to the led traffic light device.
Important! – Never connect devices
other than those specified.
During the movement, adjust the
control system of the motor force to
adapt it to the weight of the pole .
Adjust the detection sensitivity of the
metal objects of the Loop Detector
circuit . See paragraph 7 .5 - chap . 7
Further details .
Set the intensity of the braking car-
ried out during the deceleration pha-
se of the manoeuvre .
English – 11