Unit Fails to Boil
The unit has probably not been left for long enough to cool- refer to section on safety cut-out.
If using an extension lead check that it is rated at a minimum of 10 amps for 1200w or 13 amp for 1500w and fully unwound.
Unit Leaks Steam from Pressure Relief Valve
The pressure relief valve is a special low pressure valve and cannot be replaced by any other valve. If steam is leaking from the
valve, the most likely cause is a blockage in the hose. Allow the hose to cool then remove the hose and check for any blockage.
Always check the inlet in the tool you are using.
UNDER NO CIRCUMSTANCES FORCE THE VALVE SHUT. THIS IS OPERATING FOR YOUR PROTECTION.
To maintain peak performance of the unit, particularly in areas of hard water, it may be necessary to descale the element in the unit.
Proprietary kettle descaling products can be used in your unit - always follow the manufacturer's instructions.
The small steamplate is used in the same way as the large steam plate to strip wallpaper in awkward areas not easily reached with
IF YOU REQUIRE FURTHER ASSISTANCE PLEASE CONTACT OUR HELPLINE ON:
Tel: 888-783-2612 email:enquiries@earlex.com
This product is guaranteed for a period of 24 months against faulty materials and workmanship.
Whilst every possible care is taken by Earlex to ensure that our products leave the factory in good working order, Earlex cannot
under any circumstances accept liability for problems or damage caused by their subsequent use.
It is the responsibility of the user to ensure that surfaces to be treated, cleaned or stripped are suitable for steam.
This warranty does not affect your statutory rights. This warranty excludes the use for hire purposes.
In the event of a fault occuring please contact our helpline before returning the unit to our Service Department at the address
below together with a copy of your purchase receipt. All repairs will be dealt with speedily.
Earlex Inc, 8261 Hyw 73, Suite F, Stanley, N.C. 28164, USA. Tel: 704 827 7889 Fax: 704 827 7849
© Earlex Inc. 2005
TROUBLE SHOOTING
DESCALING
SMALL STEAM PLATE
(Only available with the Vap 75 Kit)
the large steam plate such as around door frames, in corners, ect.
Always wear a glove or mitt for added protection
Customer Service: Toll Free 888-783-2612 Website: www.earlex.com