OPERATING INSTRUCTIONS (CONTINUED):
REMOVING THE COLLECTED WATER:
The dehumidification of the air should result water being collected by the machine. Your model allows for
the water to be collected in a bucket (Reservoir Collection), or be hooked up via standard garden hose to a
drain located lower than the unit (Continuous Drainage).
RESERVOIR COLLECTION
• When the reservoir is full, the unit will beep eight times, the full
indicator will light and the digital display will show P2. If the unit is
on when this happens, the fan will continue spinning for 30 sec-
onds after the unit is full.
1. Slowly pull out the reservoir. Grip the left and right handles se-
curely, and carefully pull out straight so water does not spill. Do
not put the tank on the floor because the bottom of the reservoir
is uneven and water may spill. (Fig. 5)
2. Pour out the water and return the reservoir. (Fig. 6)
3. The error should clear after the reservoir is correctly positioned
and the dehumidifier should resume operation three minutes
hence.
NOTES: In order to avoid damage to the dehumidifier, do not touch
any parts inside after removing the reservoir. Be sure to push the reservoir gently all the way into the unit, as
putting it in roughly can cause problems with the operation of the unit. If water spills or is found within the
dehumidifier itself upon removing the reservoir, you should wipe it dry.
CONTINUOUS DRAINAGE
Water can be automatically emptied into a floor drain or any drain
located lower than the dehumidifier itself by attaching a standard
garden hose (5/16" - 3/4" diameter) with a 3/4" NPT female threaded
end to the drain hose adapter on the rear of the dehumidifier.
1. Remove the plastic cover from the back drain outlet of the unit and
set aside.
2. Install the female threaded end of a water hose (not included) into
adapter A.
3. Make sure the hose is secure so there are no leaks. Direct the hose
toward a floor drain, making sure that there are no kinks that will
stop the water flow. Place the end of the hose into the drain and
make sure it is level or down to let the water flow smoothly.
4. Place the reservoir back in the unit and make sure that it is seated
correctly.
5. Select the desired humidity setting and fan speed on the unit to
commence continuous draining.
8
Fig. 5
Fig. 6
Fig. 7
Fig. 8