FLAEM 4Neb Manual De Instrucciones página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
SOFTTOUCH FACE MASKS
Soft
biocompatible
material
Dispersion
Limiting Vent
During the inspiratory phase,
the tab, acting as a Dispersion
Limiting Device, bends inwards
towards the mask.
CLEANING SANITISATION DISINFECTION
Switch off the device before any cleaning procedure and unplug the power cable from
the socket.
DEVICE AND TUBING EXTERIOR
Use only a damp cloth with antibacterial soap (non-abrasive and with no solvents
of any sort).
ACCESSORIES
To disassemble the bowl, firmly grasp the bowl body and then use your other hand to
rotate the particle size regulator (C1.1) clockwise until it is ejected from the upper part
(C1.2) as a result of unscrewing. The components can then be disassembled (regulator
C1.1a, valve C1.1b, selector C1.1c and upper part C1.2) to be cleaned. The nozzle (C1.3)
is interference fitted in the upper part (C1.2) and can be extracted by simply pulling it
outwards.
Then proceed according to the following instructions.
SANITISATION
Before and after each use, sanitise the nebuliser cup and the accessories, choosing
one of the methods described below.
method A: sanitise accessories C1.1-C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4
under potable hot water (approximately 40 °C) with a gentle, non abrasive dish de-
tergent.
method B: sanitise accessories C1.1-C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4
in the dishwasher with a hot cycle.
method C: sanitise accessories C1.1-C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4
by immersing them in a solution of 50% water and 50% white vinegar, then rinse
thoroughly under potable hot water (approximately 40 °C).
If you want to also perform the cleaning for DISINFECTION, jump to the DISINFEC-
TION paragraph.
After having sanitised the accessories, shake them vigorously and place them on a
paper towel. Alternatively, dry them with a jet of hot air (for example, a hair dryer).
DISINFECTION
After sanitising the nebuliser cup and the accessories, disinfect them choosing one
of the methods described below.
method A: Accessories C1.1-C1.1a-C1.1b-C1.1c-C1.2-C1.3-C1.4-C2-C3-C4 can be
disinfected.
SoftTouch masks have an outer edge made of
soft biocompatible material that ensures excel-
lent adherence to the face, and is also equipped
with an innovative Dispersion Limiting Device.
These distinctive elements that distinguish it allow
greater sedimentation of medication in the patient
and also limit dispersion.
During the expiratory phase, the
tab, acting as a Dispersion Lim-
iting Device, bends outwards
from the mask.
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

P0711em-1 f400

Tabla de contenido