pack is defective and should be returned to a service center or other
collection site for recycling. If the new battery pack elicits the same
trouble indication as the original, have the charger and the battery
pack tested at an authorized service center.
HOT/COLD DELAY
This charger has a hot/cold delay feature: When the charger detects
a battery that is too hot or too cold, it automatically starts a delay,
suspending charging. The red light will continue to blink, but a yellow
indicator light will be illuminated during this suspension.
Once the battery has reached an optimum temperature, the yellow
light will turn off and the charger will automatically resume the
charging procedure. This feature ensures maximum battery life.
LEAVING THE BATTERY PACK IN THE CHARGER
The charger and battery pack can be left connected with the charge
indicator showing Pack Charged.
WEAK BATTERY PACKS: Weak batteries will continue to function
but should not be expected to perform as much work.
FAULTY BATTERY PACKS: This charger will not charge a faulty
battery pack. The charger will indicate faulty battery pack by refusing
to light
NOTE: This could also mean a problem with a charger.
Wall Mounting
These chargers are designed to be wall mountable or to sit upright on
a table or work surface.
If wall mounting, locate the charger within reach of an electrical outlet.
Mount the charger securely using drywall screws at least 1" (25.4 mm)
long, screwed into wood to an optimal depth leaving approximately
7/32" (5.5 mm) of the screw exposed.