5. LOGIC ADJUSTMENTS
TRIMMER
FR.
Motor torque adjustment. The trimmer is set to provide sufficient thrust to work the gate
without exceeding the limits established by current standards (EN 12453). Turning the
trimmer clockwise (+) increases the motor torque, turning it anticlockwise (-) reduces it.
SENS
Adjustable only with ENCODER enabled (DIP 11 ON).
Obstacle detection additional adjustment;
Note: by rotating the TRIMMER FR. clockwise the sensitivity to obstacles of the op-
eraor decreases and therefore the thrust force increases; vice-versa, by rotating it an-
ti-clockwise, the sensitivity to obstacles of the operator increases and therefore the
thrust force decreases.
WARNING: with the trimmer at maximum, the obstacle detection is disabled!!
T.C.A.
Automatic closing time adjustment from 5 to 120 seconds.
Dip switch
AUTOMATIC
1
CLOSING
input for PHOTOCELLS OR SAFETY DEVICES active during closure (Normally
Closed contact); They stop the gate during closing and totally reopen it; they
temporarily stop the gate during opening in order to allow the obstacle to
be removed (if dip switch n° 3 set to ON), (10= Common). If there is more
than one safety device, connect all the NC contacts IN SERIES.
Note: the photocell transmitter must always be supplied by terminals
no. 13 - 15, since the safety system test (photo-test) is carried out
on it. To override the testing of the safety system, or when the
photocells are not used, set dip-switch no. 6 to OFF. If the photo-test
is not successful, the control unit will not operate.
24V AC 10W output to POWER THE RX AND/OR OTHER TX OF OHER
INSTALLED PHOTOCELLSPHOTOCELLS AND/OR EXTERNAL RECEIVERS,
etc.; connect a max. of 3 pair of photocells. 13= 0V AC, 14= 24V AC;
24V AC 10 W POWER output for PHOTOCELL TX (only the one that
performs the Phototest) max. no. 1 photocell transmitter.
13= 0V AC, 15= 24V AC;
GATE OPEN LED output 24V AC - max. 3W; during opening of the gate the
warning light flashes slowly, when the gate is open it remains steadily
illuminated and during closure it flashes twice as fast. 16= 0V AC, 17=
24V AC;
2nd RADIO CHANNEL output (its operation depends on dip-switches nos.
7 - 8) to be used for opening/closing another gate, for controlling garden
lights or for the "ZONE LIGHTING" function;
Warning: to connect other devices to the 2nd Radio Channel (area
lighting, pumps, etc.), use an additional auxiliary relay.
433,92 MHz built-in RX antenna input;
20= EARTH, 21= SIGNAL;
quick coupling for LIMIT SWITCH connection (Normally Closed contacts).
Orange= Closure Limit Switch (CLS),
ed= Opening Limit Switch (OLS), grey= Common (COM);
quick coupling for ENCODER connection. Blue= 0V DC (GND), brown= 5V
DC (+5V), white= ENCODER SIGNAL (ENC);
faston for motor start-up CAPACITOR connection;
quick coupling for 230 Vac single-phase MOTOR connection common=
BLUE (M-COM); closure= BROWN (M-CL); opening= BLACK (M-OP).
after opening, the gate automatically closes when the delay set on the
On
T.C.A. trimmer expires.
Off
automatic closing disabled.