5.
Scope of delivery
Item
Description
1
Cover plate with control electronics and sensors
2
Self-closing solenoid valve cartridge
3
Battery box
4
Mounting frame (fastened in cover plate)
5
Extra items:
4 cheese-head screws, 4 plain washers
Installation and operating instructions
6.
Dimensions
7.
Installation example
8.
Installation example for AQUARAPID installation element
9.
Pre-fabricated kit assembly
9.1
Loosen the screws.
9.2
Cut shell protection so it is flush with the front edge of the tiles.
9.3
Close the flow volume regulator with a screwdriver, 8 mm head width.
☞
Screw flow volume regulator up to the stop limit.
!
Caution!
Do not remove the retaining ring.
9.4
Remove the flushing plugs (SW 30).
9.5
Screw on the solenoid valve cartridge.
9.6
Use the flushing plugs as an assembly key to tighten the solenoid valve cartridge.
☞
Important!
Carefully tighten the solenoid valve cartridge.
!
Caution!
Keep the flushing plugs in the flush-mounting cabinet to enable removal of the solenoid
valve cartridge at a later date.
Remove the protective earth conductor cable (a).
9.7
9.8
Open flow volume regulator. (Water flow must stop after a short period.)
☞
Screw flow volume regulator up to the stop limit.
5