Installation
5 .2 Installing the Relifix V 516
Proceed as follows:
1 Strip the cables as shown in the figure and align the
cores.
15 mm
25 mm
Stripping the cables.
2 Align the cores before connecting.
Aligning the cores.
3 Connect the cores with the connector block.
f Note the tightening torque of 3 Nm.
Connecting the cores.
4 Open the shell.
Opening the shell.
8
3 Nm
Installation Instructions • Relifix • 11-2016
5 Cut-in all four brush seals according the diameter of the
cables.
Cutting the brush seals.
6 Position the connector block between the higher ribbed
markings in the shell.
Inserting the connector block.
7 Close the shell until the locking mechanism engages.
Closing the shell.
A small amount of gel must emerge around the cable sheath
while closing the shell to be sure that the joint is perfect
protected against dirt and moisture.