tau DC19 Guía Para La Instalación página 23

Panel de control para puerta automática deslizante.
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

21 - 20
INTERLOCK
SIDE SENSOR
22 - 20
(N.C.)
(20= Common)
STOP/
23 - 20
ANTI-PANIC
(N.C.)
NOTE: The STOP lock/function blocks any movement in progress of the automation, while
the ANTI-PANIC lock/function stops the movement in progress of the automation and
then resumes with a slow closing once the function is restored.
N.B.: With DIP9 ON the input of terminal 25 (Stop / Antipanic) changes use. See Interlock Function.
CONNECTOR J17:
24 - 25
MECHANICAL SWITCH
26 - 27
WARNING: In case neither the mechanical selector it is necessary to jumper wire
terminals 24 - 26.
SM
0419
M1
M2
1
2
3
4
CONNECTOR
J9 -
CONNECTOR
J10 -
Closed
Opening
Closing
Open
In pause
Closed
Opening
Closing
Open
In pause
Closed
Opening
Closing
Open
In pause
24= Commun
25= Switch B0
26= Switch B1
27= Switch B2
HOLD OPEN =
WINTER OPENING =
AUTO =
EXIT ONLY =
LOCK =
electric block connection (12V DC).
output connection.
Prevents the opening of the other door when the
Interlock is operating
None.
None.
None.
None.
None.
Opening continues at reduced speed.
None.
None.
None.
The door does not open so long as the input is busy.
It stops the automation.
It stops the automation.
The door does not close so long as the input is busy.
The door does not open so long as the input is
busy. Once free, the door closes at reduced speed
after 5 seconds.
Connections:
Selector
1
2
3
4
Keeps door fully open.
To have a reduced
All Opening Inputs enabled-
Disables Outside Radar.
Keeps door closed, allowing opening
only with EMERGENCY Input (with Dip
#1 on SW1 on ON).
23
Control Panel
24
25
26
27
aperture.

Publicidad

Tabla de contenido
loading

Tabla de contenido