tau DC19 Guía Para La Instalación página 24

Panel de control para puerta automática deslizante.
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CONNECTOR J10:
Terminals
4
AUTOMATION OPEN LIGHT
5
POSITIVE
6
INTERLOCK OUTPUT
7
COMMUN
CONNECTOR J11 - battery charger board connector.
CONNECTOR J12 - not used.
CONNECTOR J13 - battery connector.
CONNECTOR J14 - transformer primary connector.
CONNECTOR J15 - 230V 50Hz supply input connector.
CONNECTOR J6 - transformer secondary connector.
JUMPER J18 - 12/5 VDC encoder supply selection (leave it on 12 Vdc as settled in the factory)
CONNECTOR J15:
Terminals
1
2
3
DFC PHOTOCELLS – CONNECTION
It is possible to connect up to 2 pairs of photocells using terminals 9 (power supply, brown wires),
10 (common, blue wires), 15 (signal, black wire of the 1st pair receiver) and 16 (signal, black wire of
the 2nd pair receiver if used).
Important: if a 2
pair of photocells is connected, set DIP # 4 on SW1 to OFF).
nd
Black wire of the transmitter will not be connected.
Suggestions
To avoid interferences due to peaks or inductive current, make sure that power cables of the photo-
cell's sensor are separated from other power cables, such as the main power supply or other power
cables not used for the door.
The first couple of photocells FT1/FR1 has to be installed 1mt above the ground level, while the
second couple (optional recommended) FT2/FR2 at 50 cm from the ground level (see the diagram
below)
Wire close to the photocell head must not be stretched.
Input/Output
Input/Output
PHASE
GROUND
NEUTRAL
Description
24V DC, max. 3 W
24v cc
INTERLOCK CONTACT
COMMUN INTERLOCK CONTACT
Description
230V AC
230V AC
24
wrong
correct

Publicidad

Tabla de contenido
loading

Tabla de contenido