9912 Vision System Specifications

Specifications
Power Consumption
Power Output
1
Case Temperature
Storage Temperature
Humidity
Protection
Shock (Shipping and Storage)
Vibration (Shipping and Storage)
1
To verify case temperature, use the EV GetSystemConfig("Internal.Temperature") Extended Native Mode
command. When issued, it returns the vision system internal temperature in degrees Celsius, which is
approximately 3 to 5 degrees above the vision system case temperature. For more information, see the In-Sight
Explorer Help file. A thermal scanner can also be used to determine the vision system case temperature. Additional
cooling measures are required if the case temperature cannot be kept below 50°C. Examples of such measures
include: extra heat sinking and/or air movement.
2
Before you ship this product or any machinery that contains it, remove lenses that weigh more than 350 grams.
24VDC ±10%, 1.5A maximum
24VDC @ 750mA maximum to external light.
0°C to 50°C (32°F to 122°F).
-20°C to 80°C (-4°F to 176°F)
< 80% non-condensing
IP67 with all cables properly attached (or the provided connector
plug installed), the IP67-rated cover properly installed, and the
Micro SD card cover fastened in place.
IEC60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y,
Z) axis) 80 Gs (800m/s
cable plugs and a 350 gram or lighter lens attached.
2
IEC60068-2-6: vibration test in each of the three main axis for 2
hours @ 10 Gs (10 to 500 Hz at 100m/s
cable plugs and a 350 gram or lighter lens attached.
15
9912
2
at 11ms, half-sinusoidal) with cables or
9912C
2
/ 15mm) with cables or
®