Performance Data Sheet
SmartWater
Filtration
System
MWF Cartridge
This system has been tested according to NSF/ANS142/53for reduction of the substances listedbelow.
The concentrationof the indicatedsubstances in water enteringthe system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142_3o*
'100%safety factors built in for unmetered usage)
Parameter
USEPA
]nfluent
MCL
Challenge
Concentration
(]florin(
--
2.0 rag/L_+ ]0%
T&O
--
--
Pani(ulate**
--
_>10,000 parti(les/ml,
Standard
No. 42: Aesthetic
EffeOs
lnfluent
Effluent
Average
Average
Maximmn
].96 rag/l,
0.06 Ing/l,
0.] ] rag/l,
(i,400,000 #/mE
58,833 #/mL
150,000 #/ml,
Standard
No. 53: Health
Effects
Parameter
USEPA
MCL
0.5 NT[
_> 99.95!_ Rc(/ucthm
_> 9!1% Rcd/tction
0.015 rag/l,
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 rag/I,
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
0.(X)3 mg/L
"IinSidiw
(Xsts
_sl)estos
[ _ea(/at pH 6.5
][_ea(/at pH 8.5
M_r/ur} at pl 16.5
M_r/ur} at pl i 8.5
Nachlor
1.indane
2,€1)
"Ibxaph_ nc
Benz( n(
Cafl)ofilran
1,4dich/0mbenzene
Atrazin_
/xffluent
hffluent
Challenge
Concentration
Average
11 ± 1 NT( '***
10.5 NI'('
.Minilnm_ 50,(}00 l,
1] 8,750 #/l,
] (F to 10'sfibers/l _; > ]()pro
57 MF/I,
0.15 mg/L ± 1()5?i
0.1 ,',67 rag/l,
0.] 5 mg/][, ± ]()!_i
0.] 433 mg/l,
0.006 mg/L ± ] 0!i
0.0059 mg/I,
0.006 mg/L ± ] 0!1
0.0057 mg/I,
0.04 mg/L ± 10%
0.03(i7 mg/I,
0.002 mg/L + 10!_
0.0020 rag/I,
0.210 mg/L + 10!_
02033 rag/I,
0.015 rag/i,±
10%
0.0160 rag/I,
0.00100 rag/I,
0.015 rag/L±
10!_
0.0145 rag/I,
(}.(}0050(}mg/L
(}.(180mg/L ± 10!_
0.0830 rag/I,
(}.(}0100(}mg/L
0.225 rag/L±
10!_
02283 rag/I,
0.(}00500 mg/L
0.(}09 mg/L ± 10!_
0.0087 rag/I,
< 0.(}005 mg/L
Effluent
Average
Maxlmtml
0.14 NI'( '
0.28 NTL
< 1 #/I,
4 #/I,
0.996 MF/I,
< 1 MF/I,
< 0.00] */N/I,
< 0.001 rag/l,
< 0.001 mg/L
< 0.001 mg/l,
0.000350 mg/L
0.0007 mg/L
0.000325 mg/L
0.000(i mg/L
0.00023 mg/L
0.0004 mg/L
< 0.00(X)2 rag/q,
< 0.(}0002 mg/L
0.00337 mg/L
0.011000 rag/I,
0.001000 rag/I,
0.000500 rag/I,
0.001000 rag/I,
0.000500 rag/I,
< 0.0005 mg/L
% Reduction
Average
Minimum
96.77%
!14.74%
9!).14%
!17.97%
Min. Required
Reduction
> 5(1%
>_85!_i
% Reduction
Average
Minimum
98.54%
97.20%
> 9!).!19%
> 9!).!19%
99.60%
99.39!_i
99.36%
9!).29%
99.30%
9!).29%
94.70%
87.5()!_i
93.20%
89.29%
99.34%
98.67%
99.0t1%
98.95%
98.32%
94.50%
93.44%
91.67%
96.51%
95.83%
98.78%
98.65%
9{).78%
99.77%
94.22%
93.33%
Min. Required
Reduction
0.5 NT( '
_> 99.95%
_>99%
0.010 rag/I,
0.0] 0 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
(}.04 rag/I,
0.075 mg/L
0.003 mg/L
Tested usfl_g a f/ow rate of O.5O gpm; pressure of 6Opsig pH of 7,5_+0,5; temp, of 68°_+ 5°F(20°_+3°C1
_ Measurement in Partic/es/m/, Partic/es used were 0,5-1 microns
.... NTU=Nephe/ometric Turbidity units
Operating Specifications
[] (:apacit}:
certified
h)r
up to 300
gall(ms
( 11 .,a l) ; up to six months
h)r models
without
a replacement
filter
indicator
light;
up to one
_ear
fi)r models
_dth
a replacement
filter
indicator
light
[] Pressure
requirement:
40-12(/psi
(2.8-8.2
bar),
non-shock
[] Temperature:
33-100°F
(0.6-38"(:)
[] FII)_
rate:
0.5 gpm
(1.9
lpm)
General Installation/Operation/Maintenance
Requirements
[] Hush new c'_rtrid-e at hdl flo,a h)r 3 minutes
to I
,
,
_
)urge
out
trapped
air.
[] Replace
c'u'tridoe, _
raven
the
indicator
light
flashes
or ",,4_ter flow
rate
is reduced
on non-indicator
units.
Special Notices
[] Installation
instructions,
parts
and
serG(e
a_ailabilit),
and
standard
warrant}
are
included
with
the
product
when
shipped.
[] This
drinldng
water
s}stem
I/it/st
be maintained
according
to Illanttfitcttll'el"S
illStl fictions,
including
replacement
of filter
cartridges.
[] Do
not
use _ith
_ater
that
is
microbi(dogicall}
tmsafe
or of
unknown
quality
_ithout
adequate
disinfection
before
or
after
the
sxstem.
Sxstems
certified
for
cxst
reducti(m
max
be used
on
disinfected
water
that
me}
contain
filterable
cxsts.
[] The
contaminants
or other
substances
remoxed
or redtlced
b_ this
water
treatment
s}stem
are
not
necessarilx
in )our
water.
[] Check
for
compliance
with
the
state
and
local
laws
and
regulations.
[] Note
that
while the
testing
was perfl)rmed
under
standard
laboratorx,
clmditions,
actual
performance
me}
vat}.
S}stems
must
be installed
and
operated
in accordance
vJth
mantdhcturer's
recommended
procedm'es
and guidelines.
Stmldard
No. 42: Aeslhetic
Effects
Chemical
Lnit
Chlorine
Taste m_d Odor
Methmfital
Filtration
Lnit
Parti(ulat(
Reduction,
Class I
System
"[-(,st(d
and
Certified
by NSF International
against
ANSI!NSF
Standard
42 & 53 for tile
reduction
of:
Standard
No.
53: Health
Effects
Chemical
Reduction
Unit
LMachlor and
Atrazine
Re(hlction
Benzene
and
Carbofuran
Reduction
1,4 dichlor(lbenzene
and
2,44)
Reduction
Lead
and
IAn(lane
Reduction
Mercmy
and
Toxaphene
Reduction
Mechanical
Fihration
[nit
Turl)iditv
Reduction
Cyst all({ Asbestos
Re(luction
Malmthctured
tot: General
Electric Colnpal_y, Louisville,
KY 40225
EPA EST No. 070595-MN-001