Connecting The Remote Controller; Connecting The Power Supply Unit - Honeywell HR 40 Instrucciones De Montaje Y De Manejo

Regulador de radiador
Ocultar thumbs Ver también para HR 40:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 120

Connecting the remote controller

If the location of the installation is not easily accessible, or for more comfort,
connect the HCW 23 remote controller.
Note: A remote controller can only control one HR 40. The remote controller
is connected to the HR 40 via the included HCV 23 cable type.
Important: The remote controller must only be connected when it is not
conducting current!
1. Remove the batteries from the HR 40.
2. Use a screwdriver to lever off the cover (A) on the right-hand side of the
control unit (see Fig. H).
3. Connecting the connecting lead:
See the installation instructions for the HCW 23-K.
4. Put the batteries back in the HR 40.
Changing the room temperature with the remote controller
With the HCW 23 remote controller you can change the selected setpoint
temperature by ± 12 °C. The range of adjustment of the HR 40 remains
8 – 28 °C. The
Within approx. 3 minutes the display will show the new setpoint temperature
which has been set.

Connecting the power supply unit

The HR 40 can be supplied with power from the HN 40 power supply unit. For
installation instructions, please refer to the adapter manual.
32
and
functions cannot be adjusted.

Publicidad

Tabla de contenido
loading

Tabla de contenido