Operating The Device; Periodic Maintenance - TESY ES/RC GCA 10 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
VI.

OPERATING THE DEVICE

EN
Before initial start of the device, please make sure that
the water heater has been correctly connected to the
electrical network and that it is filled up with water.
Switching on the water heater is done through the device
incorporated in the installation, which is described in sub-
item 3.2 of paragraph V, or by inserting the plug into an
electrical socket (for models with cord with a plug).
Clarification to Fig.6:
Operation modes:
1.
Position (
) anti-freezing mode
WARNING: The electrical power supply of the device
should be switched on. The safety valve and the pipe
connecting it to the device must be secured against freezing.
2.
Position (
) maximum temperature
3.
Position (
) at this mode the water temperature
reaches about 60°С. In this way heat losses are reduced.
4.
Light indicator – at heating mode it is lit in red, and it
is lit in blue when the water has been heated up and the
thermostat has switched off.
5.
Regulator knob – for temperature setting
Water heaters with electrical-mechanical POP-UP
operation:
1.
Push the knob to pop-up Fig. 7а.
2.
Set the temperature of the water heater Fig. 7b
This setting allows for gradual temperature adjustment.
3.
Push the knob to retract Fig. 7c
WARNING! Once a month set the knob to the
position 'maximum temperature' for a period of 24
hours (unless the device is constantly operated in this mode).
Thus you will ensure better hygiene of the heated water.
RUST PROTECTION MAGNESIUM ANODE
VII.
The magnesium anode protects the water tank's inner
surface from corrosion. The anode element is an element
undergoing wear and tear and is subject to periodic
replacement. This is cost for the user.
In view of the long-term and accident free use of your water
heater, the manufacturer recommends periodic inspections
of the magnesium anode's condition by a qualified
technician and replacement whenever required, and this
could be performed during the appliance's technical
preventive maintenance.
For replacements, please contact the authorized service
stations!
VIII.

PERIODIC MAINTENANCE

Under normal use of the heater, under the influence of
high temperature, lime scale /the so-called lime scale
layer/ is deposited upon the heating element's surface. This
worsens the heat exchange between the heating element
10
Instructions for use and maintenance
and water. The heating element's surface temperature
increases along /of boiling water/. The thermoregulator
begins to switch on and off more frequently. A ''deceptive"
activation of the thermal protection is possible. Due to
these facts, the manufacturer recommends preventive
maintenance of your water heater every two years by an
authorized service center or service base. This protective
maintenance must include cleaning and inspection of
the anode protector (for water heaters with glass-ceramic
coating), which shall be replace with a new one if need
arises.
In order to clean the appliances use a damp cloth. Do not
clean with abrasive or solvent content detergents. Do not
pour water over the appliance.
The manufacturer does not bare the responsibility
for all consequences caused by not obeying the
instructions, given hereby.
Environmental protection instructions.
Old electric appliances contain prescious materials
and must not be disposed with the domestic
waste! Please make your active contribution to the
protection of the environment and dispose of the
appliance in the stations organized for the purpose
(if available).
DESCRIPTION TO ANNEX I
(1) supplier's name or trade mark
(2) supplier's model identifier (3) the declared load
profile, expressed by the appropriate letter and typical usage
in accordance with Table 3 of Annex VII (4) the water heating
energy efficiency class of the model, determined in
accordance with point 1 of Annex II (5) the water heating
energy efficiency in %, rounded to the nearest integer (6) the
annual electricity consumption in kWh in terms of final
energy and/or the annual fuel consumption in GJ in terms of
GCV, rounded to the nearest integer and calculated in
accordance with point 4 of Annex VIII (7) the thermostat
temperature settings of the water heater, as placed on the
market (8) the daily electricity consumption Q elec in kWh,
rounded to three decimal places (9) the declared load profile,
expressed by the appropriate letter in accordance with Table
1 of this Annex (10) the mixed water at 40 °C V40 in litres,
rounded to the nearest integer;(11) maximum temperature
of the thermostat (12) 'out of the box-mode' is the standard
operating condition, setting or mode set by the manufacturer
at factory level, to be active immediately after the appliance
installation, suitable for normal use by the end-user
according to the water tapping pattern for which the product
has been designed and placed on the market (13) the water
heating energy efficiency in %, rounded to one decimal place
(14) All specific precautions for assembly, installation and
maintenance are described in the operating and installation
instructions. Read and follow the operating and installation
instructions. (15) All of the data that is included in the
product information was determined by applying the
specifications of the relevant European directives. Differences
to product information listed elsewhere may result in
different test conditions. Only the data that is contained in
this product information is applicable and valid.