RECOMMENDATIONS FOR REPLACING PARTS
Before carrying out any replacement procedure, ac-
tivate all the safety devices provided and decide
whether staff at work and those in the vicinity
should be informed. In particular, turn off the gas
supply tap, cut off the electricity supply using the
master switch and prevent access to all devices
that might cause unexpected health and safety haz-
ards if turned on. If worn parts have to be replaced,
use original spare parts only.
REPLACEMENT OF THE BURNER NOZZLE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Unscrew the nozzle (B) and replace it with
the one suitable for the type of gas in use
(see table at back of manual).
4 - Close the hatch (A).
IT
GB
DE
REPLACING THE BURNER AIR BUSHING
To carry out this operation, proceed as follows.
FR
1 - Turn off the gas supply tap.
2 - Open the hatch (A).
3 - Undo the screw (B).
ES
4 - Extract the bushing (C) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Adjust the position of the bushing (C) (see
pag.23).
6 - Tighten the screw (B).
7 - Close the hatch (A).
English
REPLACING PARTS
- 24 -
The manufacturer declines all responsibly for injury
or damage to components due to the use of non
original parts, or extraordinary work on the appli-
ance which may modify the safety requirements
without the manufacturer's authorisation. When or-
dering components, follow the instructions provided
in the parts catalogue.
A
A
9
B
IDM-39603311700.tif
C
B
IDM-39603314700.tif