Assembling The Dosatron - dosatron D 8 RE 2 Manual De Utilización

Ocultar thumbs Ver también para D 8 RE 2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52

ASSEMBLING THE DOSATRON

B
©
DOSATRON INTERNATIONAL / 34
A
C
Fig. 1
ASSEMBLY SHOULD BE CARRIED OUT WITHOUT THE USE OF TOOLS
The DOSATRON is delivered with :
- a mounting bracket,
- a suction tube with a strainer.
The bracket enables the DOSATRON to be fixed to a wall.
- Slide the Dosatron's dove-tail fittings (Fig. 1-A) into the wall bracket (Fig. 1-B).
- Remove the plastic caps (Fig. 1-C) which block the inlet and outlet of your
DOSATRON before connecting to the water supply.
RECOMMENDATIONS
The DOSATRON can be connected to the water supply by means of
Ø 40 x 49 mm [1 1/2"] bore flexible hose and hose tail fittings with hose clips.
Make certain that the water flows in the direction of the arrows on the pump
body.
The DOSATRON is delivered with a suction tube (cut it to the needed length)
enabling its use with a large capacity concentrate container.
The tube must be fitted with its strainer and weights.
The instructions for fitting the tube are to be found in the specific chapter.
NOTE : The maximum suction height is 4 meters (13 vertical feet).
Fit the tube, equipped with its strainer and its weight, and immerse it in the
solution to be injected.
©
©
DOSATRON INTERNATIONAL / 35
DOSATRON INTERNATIONAL / 35
.
Torque 30 N
m
.
thus 3 kg
m
(Remember : 1 N . m = 0.1 DaN.m)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

D 8 gl 2D 8 re 5

Tabla de contenido