13.2 Settings For Tig Welding - INE SKYLINE HFP3000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INE SpA Via Facca, 10 - 35013 Cittadella - PADOVA - ITALIA Tel. 049/9481111 - Fax 049/9400249 - ine@ine.it - www.ine.it

13.2 Settings for TIG welding

To select the type of welding required:
Press and hold down 'E2' for a few seconds, or the
icon
on the display; the display changes as
shown below.
E1
Turn one of the rotary switches and select the icon
for the welding process: TIG lift
confirm press 'E2'. Alternatively, tap the icon on the
screen.
Turn one of the rotary switches and select the
operating mode: 2-step
to confirm press 'E2'. Alternatively, tap the icon on
the screen.
Turn one of the rotary switches and select the
current constant
confirm press 'E2'. Or tap the corresponding icon on
the screen.
If timed welding is required, turn one of the rotary
switches and select the icon
'E2'. Alternatively, tap the icon on the screen. The
welding duration can be set on the main screen by
simply selecting the 'SPOT' parameter.
Other welding parameters can be set by selecting
the SETTINGS
icon (see below).
To manage the programs
the sections that follow.
Settings are confirmed by tapping HOME
following confirmation the main screen reappears, or
confirmation is automatic after 10 seconds.
E2
or TIG HF
, 4-step
, 2-level
or pulsating current
; to
; to confirm press
and jobs
, refer to
Below are the main screens found in TIG:
E1
TIG 2-step at constant current
; to
E1
TIG 4-step at pulsating current
;
E1
TIG 2-level with pulsating current and timed
welding duration
Using 'E1', the parameter with the blue background can
be set. 'E2' is used to set the parameter with the green
background.
You can select the parameters controlled by the two
;
rotary switches by simply pressing the blue or green
knob. The associated parameters are highlighted on
the diagram at the top of the screen.
E1
The red background indicates there is welding voltage
at the bushings.
Page 27
E2
E2
E2
E2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Skyline hfp4000Skyline hfp5000

Tabla de contenido