To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
IT
dure has been carried out (see page 18). Be-
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
GB
ed pressure for the type of gas in use (see
table at back of manual).
DE
FR
ES
English
B
A
B
A
one suitable for the type of gas in use (see table
at back of manual).
5 - After making the setting, seal the screw with
paint.
6 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
C
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - After making the setting, seal the screw with
paint.
6 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
C
- 20 -
D
IDM-39618301200.tif
D
IDM-39618301300.tif