GENERAL GUIDELINES

• Before travelling or sleeping, check water level of tank, taking into account that approximate consumption is
1.5 l/h.
• Every 2 months or according to needs, clean humidity filter (1), filter tank (2). (See photo on last page).
• Humidity filter (1) will have to be changed at least every 2 years or before if environmental circumstances require it.
• Active carbon filters (3) will have to be changed every year but can be cleaned according to needs with low
pressure air. (See photo on last page).
• In winter it is convenient to remove water from circuit to avoid damages due to possible frost. In winter and in
case of pressure cleaning with a hose, cover air inlet with part (A), delivered by the installer to the user. Do not
forget to disassemble these parts when equipment is switched back on. (On last page).
• If it is necessary to fold cabin down, after switching equipment off, wait between 3 to 4 min. to allow water to
fully return to main tank.
• The anti-return valve must be replaced each 12 months.

WATER TREATMENT

The following norms must be observed:
• BYCOOL evaporation system contains a product (4) (See photo on last page) for water treatment, elaborated in
accordance with current norms, which maintains water in ideal conditions for 6 months and reduces incrustation
formation produced by impurities and corrosion, while it avoids proliferation of fungi, bacterium, etc. that could
be harmful to health.
• The product is situated in drain lid of tank, so that it is always in contact with water present in lower part of the
circuit. In order to change it, lower lid has to be unscrewed and replaced by another one (ref. 091.024.0005).
• To purchase replacement product, please contact air conditioner supplier or dirna Bergstrom by calling the
number indicated on last page of handbook.
• The ventury sustem filter (5) (see last page picture) must be cleaned each 6 months and must be replaced each
12 months.
ATTENTION!
TANK SHOULD ALWAYS BE FILLED WITH DRINKING WATER. Do not add to water odorant products or any
other not authorised by equipment manufacturer.
• At least every 6 months, a full cleaning of all the water circuit will have to be done, following the instructions
below:
a- Empty all the water circuit, removing lower tank cap that contains maintenance product.
b- Refill it, up to approximately half tank capacity, using a solution of drinking water and bleaching soda (20%
of house bleach). Switch equipment on, at minimum air speed and maximum operation time of water pump
and leave it running for approximately 2 hours.
c- Completely empty circuit and rinse main tank thoroughly using pressured water to eliminate residues left
by previous operation.
d- If air conditioner is going to be used, refill circuit using drinking water and add a new dose of maintenance
product.
ALARM CLOCK: when button is pushed once, red light is switched on. If pushed twice, a whistle will blow (1/2
hour); if pushed thrice, two whistles will blow (1 hour); if pushed four times, three whistles will blow (1h ½) and if
pushed five times, four whistles will blow (2 hours). If user carries on pushing button, it will go back to beginning.
IMPORTANT NOTE:
those related to water use and treatment to ensure both the equipment operation and hygiene and health
conditions.
In case they should not be respected, DIRNA BERGSTROM is exempted from any responsibility.
Observance of previously mentioned norms is the user's sole responsibility, in particular
Air conditioning for vehicles
5