Descargar Imprimir esta página

Wiring Diagram - Ferroli ECONCEPT 51 Instrucciones De Uso, Instalación Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
ECONCEPT 51/51i - 101/101i

5.6 Wiring diagram

A
81
82
DBM12KC
16
X1
X3
278
341
186
X2
Attention : Remove the jumper on the terminal block before connecting the room thermostat or the remote timer control
A
A
Only model ECONCEPT 101/101i
16
Fan
32
Heating circulating pump
42
DHW temperature sensor (not supplied)
44
Gas valve
72
Room thermostat (not supplied)
72b
Second room thermostat (not supplied)
81
Ignition electrode
82
Detection electrode
95
Diverter valve (not supplied)
A = Heating phase
B = DHW phase
C = Neutral
NOTE: For valves with 2 wires and spring return, use the connections B and C
82
44
V1
DBM12KC
V2
X1
16
32
X3
278
341
16
114
186
X2
cod. 3540S576 - Rev. 01 - 02/2015
81
44
V1
V2
32
16
98
114
FUSE
3.15A
230V
50Hz
L
N
X01
X04
fig. 47 - Wiring diagram
98
Switch
114
Water pressure switch
130
DHW circulating pump (not supplied)
138
External probe (not supplied)
139
Remote timer control (not supplied)
186
Return sensor
278
Double sensor (Safety + Heating)
298
Cascade temperature sensor (not supplied)
299
Input 0-10 Vdc
300
Burner lit contact (voltage-free contact)
301
Fault contact (voltage-free contact)
302
Remote reset input (230 Volt)
306
Heating system circulating pump (not supplied)
307
Heating system second circulating pump (not supplied)
341
Exchanger probe
4
5 6
7
8
9
10
11 12
(
( (
(
A
B
C
301
300
302
95
13 14 15 16
17 18 19 20 21 22 23 24
25 26 27 28
72
299
138
298
72B
42
139
X03
X05
DSP12C
EN
306
130/307
29 30
59