7.4. REPLACEMENT / CLEANING NON-RETURN VALVE.
Before starting the replacement / clearing,
discharge several times and (if it was previously
installed) to dose the stopcock of the vertical waste
pipe and disconnect the unit from the power supply.
- Remove the 1 1/4" nut (A).
- Release the support flanges attaching the pipe
to the wall in order to move the pipe and to
make the dismantling easier.
- Have a container near to collect water, empty
the discharge pipe by activating the non return
valve clapper.
- Remove the clip nut (B)
- Check or replace the seal support + non-return
joint set (C).
- To assemble the valve, follow the steps in
reverse order.
Before operating the waste disposer again, and for
the purpose of eliminating air within the discharge
installation, discharge the cistern several times.
8. TECHNICAL SPECIFICATION.
Inlets:
Lavatory:
Auxiliary:
Outlet:
Discharge:
Retaining Valve:
Pump:
Voltage:
Fuse:
Consumed power:
Capacitor:
Electrical Connection:
Maximum height of discharge:
Max.Horizontal distance of discharge: 62 m
Dimensions and weight:
Dimensions:
Weight:
Weight incluiding packaging:
NOTICE: All data provided in this technical catalogue, due to the constant improvement and evolution of
our products, can be modified without prior notice. This catalogue has no contractual nature and the infor-
mation is provided in good faith.
24 - INSTRUCTIONS AND MAINTENANCE GUIDE
T-604 CS WASTE DISPOSER
Ø90 mm flexible offset coupling.
Two 1 1/2 x 40 mm auxiliary side inlets for Ø40 mm pipe.
One 1 1/2 x 40 mm auxiliary side inlet for Ø40 mm pipe.
32 mm solvent PVC pipe.(Ø22 and Ø28 mm with an adapter)
1 1/4" x32 mm that can be dismantled.
~ 240 V, AC, 50 Hz.
Thermal
0.47 kW.
14 μF / 450 V
For a standardised IEC plug
6 m
529x146x335 mm
6.8 Kg
8.2 Kg