Installation
4.2
Electrical connection
CAUTION
Damage to the device due to faulty electrical connection.
• The device must be operated with the correct connected voltage (see
name plate).
CAUTION
Damage to the device due to the use of a non-fitting or unsuitable drive control
unit.
• The control unit must support all the options attached to the device.
• Connect all the marked cable conductors.
• Do not connect any conductors that are not marked.
CAUTION
Damage or destruction of the device due to faulty electrical connection.
• The device must not be operated without an overcurrent shut-off.
• T he device must be shut off by an overcurrent shut-off when it reaches the
limit positions. The overcurrent shut-off is optionally available as an internal
or external model.
• T he customer-supplied power supply must be capable of supplying a mini-
mum current of 2 A at 24 V DC or 4 A at 12 V DC per device. If this current
is not supplied, the device cannot be shut off when it reaches the limit posi-
tions.
• I f a configuration of the device without electronics has been selected, the
overcurrent shut-off must be implemented externally by the customer.
CAUTION
Damage or destruction of the device through ingress of moisture in the connec-
tion cables.
• F or devices with protection type IP 67, the customer-provided connection of
the cable ends or connectors must also have IP 67 protection.
No circuit diagrams are listed below on account of the multitude of configuration
possibilities.
The device has to be connected in accordance with the circuit diagram enclosed
with the delivery.
Please refer to the following pages or the circuit diagram enclosed with the
delivery for connection of the option selected by you.