Installation - Pentair STA-RITE MULTI EVO Series Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
EN
INSTRUCTION MANUAL
2.2 SOUND PRESSURE LEVEL
The sound pressure level is below 70dB (LpA) on the following models: all models
2.3 MAXIMUM HEAD
See appendix
2.4 TRANSPORT AND STORAGE
On delivery, check that the electric pump has not been subject to damage during transport; in this case notify the retailer immediately.
Check procedure phases:
• check the exterior of the packaging;
• remove all product packaging material;
Use the original packaging to return the product to the retailer in the event of defects; otherwise dispose of all packaging materials
according to current local standards.
DANGER
Handle the product in observance of current accident prevention standards.
During storage, protect the product from humidity, dust, heat sources, mechanical damage and external contaminants in order to
conserve the quality of the water subsequently placed in contact with the pump.
CHAPTER 3

INSTALLATION

Install the pump on a flat surface and secure to prevent movement during start-up and operation, ensuring that there are no
obstructions to the regular flow of cooling air delivered by the motor fan. If installed for use with drinking water, clean the pump prior to
installation - also clean if left unused for prolonged periods of time.
The pump must be installed in a well-ventilated area, and relative humidity in the environment must not exceed 50% at 40°C
(condensate free).
Ensure that the installation site is sufficiently sized to enable assembly of the pump on the system and future maintenance operations.
Ensure that the pump installation room or site is not subject to the risk of flooding by the leakage of liquids or other events that may
cause submersion of the pump itself.
Ensure that the ambient temperature does not exceed the values specified on the data plate.
DANGER
To avoid breakdown of the system with the risk of physical injury, use pipelines, connectors and accessories suited to the
maximum operating pressure values.
DANGER
All pipeline connections must be made by qualified personnel in conformity with current local standards.
To avoid the need to drain the system in the event of pump maintenance, the installation of a shutoff valve is recommended, on the
suction and delivery pipelines.
DANGER
If the pump remains in operation with the delivery valve closed for more than a few seconds, the liquid will overheat. Never use
the pump with the shutoff valve closed on the delivery side.
The pump should be installed in such a way to avoid the risk of air pockets in the body or pipelines, in particular on the suction side of
the pump.
14
• inspect the product for possible
damaged parts;
• contact the retailer if any defects are
found.