Clean the terminals as follows:
1. Set the range switch to OFF position and remove the test leads from the meter.
2. Shake out any dirt which may exist in the terminals.
3. Soak a new swab with alcohol.
4. Work the swab around in every terminal.
Replacing the Battery and Fuse
Warning
To avoid false readings, which could lead to possible electric shock or personal injury, replace the batteries as soon as the
low battery indicator (
Remove test leads from the meter before opening the back cover or the battery cover.
To replace the batteries, remove the screws on the battery cover and remove the battery cover, replace the exhausted batteries with new
batteries of the same type (AA or equivalent). Reinstall the battery cover and the screws.
This meter uses one fuse: 400mA, 690V, Fast, Min. Interrupt Rating
20000A, Ø10X38mm To replace the fuse, remove the screws on the back cover and move the back cover aside gently, replace the blown
fuse with a new one of the same ratings. Reinstall the back cover and all the screws.
APPENDIX
When the meter is not in use, you can wind the test leads around the meter, if necessary, by using the following procedure:
1. Insert the plug of the black test lead into the "COM" terminal and the plug of the red test lead into the "
2. Wind the test leads anticlockwise around the meter.
3. Lay the test leads through the groove at the bottom side of ther meter (see the Bottom View) and then mount the tes lead probes
in the probe brackets.
Front View
) appears. To prevent damage or injury, install only replacement fuse of the same ratings.
Top View
Back View
29
Bottom View
Left View
Right View
" terminal.