Additional consumables and accessories can be ordered for any Forney Authorized Dealer. See
Maintenance and Parts section of this manual for additional information.
Weight: 35 Lbs. (15.88Kg)
Power Source Rating & Specifications
Rated Output Voltage
Duty Cycle, 120 VAC
Thermal Overload Protection
Input Voltage
Phase
Circuit
Generator Requirements:
Engine Drive
Output Current
Performance
Extension Cord Requirements:
Input Voltage
Phase
Cord Gauge Size
Length
Performance Data Plate
On the bottom of the Plasma System there is a plate that includes all of the operating specifications of
your Forney 250P+ Plasma System. Including the serial number of the product.
Duty Cycling & Overheating
The duty cycle is the amount of time, in minutes, that a plasma arc can remain on within a 10-minute
period when operated at an ambient temperature of 104 degrees F (40 degrees C).
• At 12 A, the arc can remain on for 2.5 minutes out of 10 minutes without causing the unit to
overheat (25% duty-cycle).
If the power supply overheats because its duty cycle is exceeded, the yellow temperature LED will
illuminate, the arc will shut off and the cooling fan will continue to run. To resume cutting, wait for the
yellow temperature LED to extinguish. NOTE: Exceeding duty cycle can damage the system and void
warranty
84.8V
25% @ 12 A
35% Duty Cycle @ 104F degrees (40C degrees)
120 VAC / 20 A, 60Hz
Single
15 Amps, with time-delay fuses (20A) or circuit breakers
2,500 W
20 Amps
Full Arc Stretch
120 VAC
Single Phase
10 AWG
33ft (10m) Suggested, 50ft (15m) Maximum
WWW.FORNEYIND.COM
17