Possible Malfunctions - Bartscher BS1240L Instrucción De Servicio

Ocultar thumbs Ver también para BS1240L:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 65
If the device
is to remain unused for a longer period of time
pull the plug from the socket;
remove all food products / dishes from the device and clean the device as
in the instructions;
leave the door open, to avoid accumulation of unpleasant smell;
cover the refrigeration unit in order to protect it against the dust.

7. Possible Malfunctions

In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Malfunction
No cooling
Insufficient
cooling capacity
Cause
• Improperly connected
power cord
• Electrical circuit safety
fuse has gone off
• Power outage
• Damaged temperature
controller
• Device is too close to
source heat or direct
sunlight
• Poor air circulation in the
device
• The device is overfilled
• Stored food is too warm
• Improperly closed door
or the door was left
open too long
• Improper temperature
setting
:
Solution
• Pull the plug and reinsert it
into the socket correctly
• Check the fuse, check the
device by connecting it to
another socket
• Check the power source
• Contact the sales agent
• Ensure sufficient distance
between the device and
heat sources
• Ensure sufficient distance
from walls and other objects
• Remove excess food
products
• Cool down the food products
before storing them in the
device
• Close the door and shorten
the time of its opening
• Set lower temperature
- 39 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

700599

Tabla de contenido