Desoutter EAB15-900 Manual De Instrucciones página 84

Ocultar thumbs Ver también para EAB15-900:
Tabla de contenido

Publicidad

6159930390_05
Mensagem
045
Anormal battery voltage
046
Anormal battery current
Anormal battery
047
behaviour
048
Battery type not allowed
205
Torque settings
206
Speed settings
210
Invalid Pset selected
211
Invalid trigger conf
212
Result not stored
216
Current high
223
Drive init error
224
IGBT too hot
227
Motor stalled
228
Drive err.
251
No Pset selected
Quando este ícone aparecer e soar a
mensagem de voz "Hardware failure"
ao ligar, solicite suporte de seu
representante Desoutter.
Solução
1- Anormal battery high voltage, check your battery.
2- This error can due to charger malfunction or end of life battery.
1- Anormal battery current consumption, check your PSet
settings.
2- This error can due to speed settings.
1- Anormal battery behaviour, check your battery.
2- If the problem occured again, change the battery with a new
one.
1- Battery type not allowed.
2- Change your battery type or your configuration.
1-Invalid Torque setting, torque is greater than tool characteristics
2-Check Pset settings with the current tool characteristics
1-Invalid speed setting, speed is greater than tool characteristics
2-Check Pset settings with the tool max. speed.
1- The Pset currently selected does not match the selectable one
in the Assembly Process.
1- The tool currently connected to the CVI3 is not equipped with
the trigger required by the tool trigger configuration
2- Adjust your tool trigger configuration to the tool connected or
change the tool according to the expected trigger configuration
1- It was not possible to persist the tightening result in the
controller
2- Contact your Desoutter representative for support
1-Max current exceeded.
2-Contact your Desoutter representative for support
1- Software failure.
2- Restart the controller.
3- If the problem occurs again, contact your Desoutter
representative for support.
1- Power electronics too warm.
2- Let the controller cool down.
1- Motor stalled (could be missing phase, wrong motortune or
power electronics failure)
2- Try once again, if the problem occurs again, contact your
Desoutter representative for support.
1- Software failure
2- Restart the controller.
3- If the problem occurs again, contact your Desoutter
representative for support
1- No Pset is selected
2- Select a Pset before start order
84 / 108
84 / 108
Português
(Portuguese)
04/2014
04/2014

Publicidad

Tabla de contenido
loading

Tabla de contenido