Electrical Installation - DURAVIT 2nd floor 760079 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12

Electrical installation

Power supply
Fuse protection
RCD
Pre-installation
> Installing a permanent power supply line:
Pre-connect a separate fuse and residual current
operating device (RCD)
Pre-connect an all-pole separating main switch
outside the prescribed safety areas (0 - 2)
Allow the supply line to protrude by 3,000 mm
> Laying the potential equalisation cable:
Allow the cable to protrude by 3,000 mm
16
Connecting the whirltub (Diagram 16)
NOTE! Avoiding any malfunctions!
Do not fasten the cables together with cable ties.
Do not install the supply line parallel to the control
cables.
I
Connect the supply line to the mains supply
socket.
II
Connect the potential equalisation cable to the
whirltub.
76xxxx xx x xx xx00:
50 Hz, 220 - 240 V AC
76xxxx xx x xx xx06:
60 Hz, 220 - 240 V AC
IN = 16 A
I
≤ 30 mA
ΔN
Safety areas in accordance with DIN VDE 0100-701
0
6 0
1
0
I
L
N
PE
II
6 0
0
2
* or the height of
the highest shower
head / water outlet
that is permanently
installed; depending
on which is higher
WH_M_Einbau_MV-AV_EasyClick/17.05.3
7

Publicidad

Tabla de contenido
loading

Tabla de contenido