Sea Level Pressure Sub Mode - Suunto ADVIZOR Manual De Instrucciones

Ocultar thumbs Ver también para ADVIZOR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 181
The Outer Circumference graphically displays the atmospheric pressure where one full circle equals 100
mbars or 1 inHg.
To view the information compiled in the 4-day memory:
PRESS the [-] button to scroll back down in increments of one hour for the first six hours, after that increments
are 6 hours.
PRESS the [+] button to scroll back up.
Note: Replacing the battery will not erase this information.

5.3 SEA LEVEL PRESSURE SUB MODE

Sea level pressure is pressure relative to sea level whereas the pressure read in the main barometer display is
absolute pressure in the current location.
In the Barometer mode, PRESS the [Select] button three times to enter this sub mode.
In the sea level pressure mode (Fig. 49):
Field 1 displays the text “SEA”;
Field 2 displays the current sea level pressure; and
Field 3 displays the current time.
If the altitude is not known, setting the sea level pressure can be used in setting the altitude measurement on
the Wristop Computer.
To set the sea level pressure (Fig. 50):
1. PRESS the [Select] button and hold in for 2 seconds. Located in Field 2, the current sea level pressure will
begin to flash.
2. PRESS the [+] button to scroll the pressure upward or PRESS the [-] button to scroll the pressure downward.
3. At the desired pressure, PRESS the [Mode] button to accept the changes and return to the main mode.
Once the user completes this process, the altitude measurement on the Wristop Computer is correct within
approximately ten meters or 30 ft.

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Metron

Tabla de contenido