Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
Operation only allowed to qualified person,
damages due to unprofessional operation or re-
move of any parts inside will not be considered
in warranty service. There are no serviceable
parts inside the device or package, service only
leaves to authorized dealers.
Never allow the optical components contact
Trouble Shooting
Problems
Device not power up
Pan/Tilt error or vibrate
LED off
Device not response
to DMX
P. 6
Tecshow ION 740z |
English version
Possible reasons
Powercon or power cable damaged
Faulty power supply
Faulty Pan/Tilt PCB
Faulty opto sensor
Cable loosen
Temperature protection
Fan not working
Faulty LED
Dimmer and strobe set at 0
Faulty power supply
Faulty communication IC
Faulty display PCB
Wrong DMX addressing
Faulty DMX cable
with oil, fat or any other liquid.
A regular clearance of the device is needed for
long-term usage, this is very helpful to maintain
the lifetime and brightness need to use a soft
and lint-free cloth to clean the optical system,
fan and air flowing tunnel.
Checking or solutions
Change a good power cable to try
Replace new power supply
Replace PT001 PCB
Replace opto sensor OP001
Check the cable connect to OP001
Check the temperature from menu
Check the fan speed info from menu
Replace new LED
Set dimmer and strobe channel at 255
Replace new power supply
Replace the IC with back-up one in the
display PCB
Replace new display PCB
Check the address and setting
Change to a good DMX cable