Installation tool / Installation
sequence
Dimensions
Technical Data
Note
Points out information to the affected
personnel, whose content is important
and must be taken into consideration.
Water connection
Warm water
Water connection
Cold water
Electrician
The installation and testing work must
be performed by a skilled electrician
in observance of VDE 0100 part 701
and IEC 60364-7-701.
Water on / off
Installation sequence
1.
Silicone (free from acetic acid!)
Plug outlets
Plug the unused outlet.
Pipe decline
%
Install water pipes for body showers
with a gradient.
Electricity on / off
1
0
1
0
Empty pipe EN20
4
English
Potential equalisation
PE
N
neutral conductor
L
conductor
FI
FI protective switch
light switch
transformer
Illuminant
connectors
Amplifier for speaker
Middle of shower stall
X
Area for required wall rein-
forcement
The wall must be reinforced in this
area.
Test certificate
Electrical connection
Preinstall electrcal power 230 V/N/PE/50 Hz
(length: 0.3 m)
The current version of the applicable regulations
from VDE, local authorities and utility companies
must be observed for electric installation work.
Residual current protection system
The system must be protected via a leakage cur-
rent protective device (RCD/ FI) with a measure-
ment difference current of ≤ 30 mA.
Arrangement of the modules
Adjust the module arrangement to the local
conditions
(Installation example see page 32 - 51)
Fastening material
Only suitable fastening material may be used!
The enclosed screws and plugs are only suitable
for concrete.
Flush piping system
To complete the installation flush out both hot and
cold water supply.
Sequence power
The performance of the waste must be of sufficient
size.
check valve
The check valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Technical Data
Operating pressure:
Recommended operating pressure: 0,15 - 0,6 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Connections:
Rate of flow by 0,3 MPa:
10750180 (1 Consumer)
10750180 (2 Consumer)
10650180
10971180
28486180
Thermal disinfection:
max. 70°C / 4 min
• The product is exclusively designed for drinking
water!
• Safety against backflow
max. 1,0 MPa
1,6 MPa
max. 80°C
65°C
G ¾ / G ½
44 l/min
55 l/min
25 l/min
55 l/min
50 l/min