Adjustment ETW
Factory reset
For the factory reset, please do the following steps:
• Activate the EasyTeach menu and keep it active for approx. 15 seconds until the LED flashes green
with double pulses. Output A1 and A2 are pulsing alternately.
• Terminate the connection.
The evaluation unit is back in delivery condition.
Test function
The test function can be used to check the control system that is connected to the sensor.
• Activate the EasyTeach menu and keep it active until the LED flashes yellow (approx. 20 seconds).
Output A1 and A2 are pulsing alternately.
The test function is activated until you terminate the connection.
After making the adjustment put the EasyTeach wire (pin 5) on GND of the supply voltage
i
(U
-). This prevents unintentional adjustments on the device.