FILTER PARTS
FRONT PART
OPTIMATIC 55
1-CE shade number standard classification
3- Delay adjustment
5- Shade
All filters are classified as indicates the CE Certificate for each model. The first number indicates the
DIN protection level of the filter when it is open (light state). The second number indicates the DIN pro-
tection level of the filter when it is closed (dark state), showing the minimum and the maximum levels
of protection. The symbol between both numbers tells us if the adjustment of the DIN level is manual
or automatic.
The following three numbers indicate the optical class, diffusion of light class and variation of luminous
transmittance class according to related European classification.
The further three numbers indicate the EU Directives with which the filter complies.
FILTER ADJUSTMENT
OPTIMATIC filters are provided with Automatic adjustment. DIN level adjustment is dependant upon
type of welding and current/amperes used. DIN level is the shade level of the filter during the welding
process.
Sensitivity
Adjusts the amount of light needed to cause the lens to change from clear to dark state.
OPTIMATIC models have low light sensitivity in the LOW position and high light sensitivity in the HIGH
position.