Jumper settings and connections
Receiver (PD140FNT60Q-02C)
Green LED
Dist
Sync
Align
Out
sets, the supply cords must be crossed to synchronize the emitter and
receiver sets.
Position 1: Disable sync function (default)
Position 2: Enable sync function
Align jumper:
The jumper enables the alignment out connector, and the yellow LED indi-
cates alignment signal strength by blinking. This jumper is used for help
with alignment of the sensors during installation.
Position 1:
Position 2:
Align out:
The connector can be used together with the
accessory cable, bought separately, and a
voltmeter. The voltage output is between 0 -
4VDC. The higher the voltage, the better the
alignment between the sensors.
Yellow LED
V+
V-
NC
C
NO
Disable alignment function (default)
Enable alignment function
Dist jumper:
The jumper sets the usable ranges
of the sensors. When installing the
sensors, set the jumper in the right
position depending on the distance
between the sensors. The default
range setting is 12 – 60 m. If the sen-
sors are used with a shorter range
and the jumper is not moved to the
right position, the optical angle will
not meet the safety standard "ESPE
type 2":
Position 1: 12 - 60 m range (default)
Position 2: 6 - 12 m range
Position 3 (removed): 0.6 - 6 m
range
Sync jumper:
The jumper must be enabled (posi-
tion 2) when using two sets of sen-
sors and an AC supply. To prevent
crosstalk between the two sensor