Typical Installations; Fully Ducted System; Central Draw Point; Simplified Installation - Broan ERV70S Guia De Instalacion

Ocultar thumbs Ver también para ERV70S:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. T
I
YPICAL
NSTALLATIONS
Use the following illustrations as guidelines to help you decide on how the unit will be installed.
All the units should be hung from the joists.
If required, bathroom fans and a range hood may be used to exhaust stale air. Also, for homes with more than one level, we recommend
one exhaust register at the highest level.
There are 3 installation methods: Fully ducted, Central Draw Point and Simplified Installation.
NOTE: An electrical outlet has to be available within 3 feet of the unit.
3.1 F
D
S
ULLY
UCTED
YSTEM
Stale air coming from the registers located at the highest level of the
house is exhausted outdoors. Fresh air from outdoors is filtered and
supplied by the register located in the lowest liveable level.
Homes with more than one level require at least one exhaust register at
the highest level.
See figure at right.
3.2 C
D
P
ENTRAL
RAW
Stale air coming from the registers located at the highest level of the
house is exhausted outdoors. Fresh air from outdoors is filtered and
supplied to the return (plenum) or the supply duct of the forced air unit.
See figure at right.
For this type of installation, it is not essential that the forced air system
blower runs when the unit is in operation, but we recommend it.
NOTE: Home with multiple forced air systems should have one unit on
each system.
3.3 S
I
IMPLIFIED
NSTALLATION
Stale air is exhausted outdoors. Fresh air from outdoors is filtered and
supplied to the return (plenum) or the supply duct of the forced air unit.
See figure at right.
To avoid cross-contamination and achieve the highest efficiencies, the
forced air system blower must always be ON.
NOTE: Home with multiple forced air systems should have one unit on
each system.
(P
RIMARILY FOR HOMES WITH RADIANT HOT WATER OR ELECTRIC BASEBOARD HEATING
(C
OINT
ONNECTION TO A FORCED AIR SYSTEM
(C
ONNECTION TO A FORCED AIR SYSTEM
VH0081
)
VH0082
)
VH0082
5
)

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Erv70tHrv80sHrv90sHrv80tHrv90t

Tabla de contenido