Propane Gas Supply Sizing - L.B.White Tradesman CP170 Manual De Usario

Ocultar thumbs Ver también para Tradesman CP170:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12
Tradesman Construction Heaters

Propane Gas Supply Sizing

The vaporization of propane is affected by several
factors: the surface area of the container, the liquid
level of propane, temperature surrounding the
container, and the relative humidity. All of these
factors are specifi c to a site. Therefore, a degree of
experience and judgement is required to select the
proper propane supply.
Although experience is the best guide, the following
recommendations can be used as a starting point.
The table is based on experience in northern
climates where cold weather and high humidity are
prevalent in the winter.
Tradesman 170 LP Recommended Propane Gas Supply
Average Temp ºF
50
°C
10
Number of 100lb.(45kg) 1
Gas Cylinders to
Use Per Heater
* When multiple LP gas supply containers are used, the containers must be manifolded together together to
allow simultaneous vapor withdrawal from all cylinders.
Tradesman 400 Recommended Gas Supply
Propane Supply Tank:
500 gallon/ 1,893 litres
1,000 gallon/3,785litres
Owner's Manual • Tradesman
If more or less favorable conditions prevail at a specifi c
site, adjustments can be made on the basis of experi-
ence.
If more than one gas supply container is used per heater,
the containers must be manifolded together to allow va-
por withdrawal simultaneously from multiple containers.
Manifold system shall be in accordance with NFPA 58.
40
30
20
4.4
-1.1
-6.7
1
1
2
Heater(s)/Container(s):
1 heater per tank
2 heaters per tank
10
0
-10
-12.2
-17.8
-23
2
2
3

Publicidad

Tabla de contenido
loading