10. Using of the menus
NB: pressure on the keys may be quick (less than 2 s) or prolonged (longer than 2 s).
i
Unless specified otherwise, quick pressure is intended.
To confirm the setting of a parameter, prolonged pressing is necessary.
10.1 Switching the display ON and OFF
The procedure to switch on the display is as follows:
•
press the ENTER key
•
the display functioning check starts
•
the first level menu is displayed
The procedure to switch off the display is as follows:
•
press the ESC key
NB: there is no automatic exit from the WZ quick configuration menu. For all the other menus,
the display switches off automatically after 60 seconds of inactivity.
10.2 Navigation keys
• The simultaneous pressing of the ↑ and ENTER keys produces an opening command.
• The simultaneous pressing of the ↓and ENTER keys produces a closing command.
• The simultaneous pressing of the ↑ and ↓ keys produces a POWER RESET command (pow-
er supply interruption and automation restart).
• Keep the UP ↑ or DOWN ↓ key pressed to begin fast menu scrolling.
To set a parameter, select the desired value and press ENTER for 2 seconds to save.
Example: setting of 30 seconds for parameter TC
• In some menus, the parameter measurement unit can be viewed by pressing the ENTER key
once the value has been displayed.
15
x 2 s
EN