12.1 SOFA1-SOFA2 or GOPAVRS self-controlled safety edge
Command
SOFA1-SOFA2
GOPAV
1
6
1
8
1
6
8
13. Outputs and accessories
Value of
Output
accessories
-
+
24V / 0.3A
0
1
GOL148REA
FLM
+LP-
FL24
24V / 25W
SOFA1-SOFA2
GOPAVRS
LAB9
AUX
BIXR2
BIXPR2
BIXLR42
LAN7S
Function
SAFETY TEST
NC
SAFETY STOP
CLOSURE
NC
SAFETY DEVICE
CLOSING/
NC
OPENING
SAFETY DEVICE
Power supply to accessories
Output for power supply to external accessories.
NB: the maximum absorption of 0.3A corresponds to the sum of all
terminals 1.
If the ZENPRS radio receiver is used (868.35 MHz), connect the supplied
antenna wire (90mm).
Flashing light
The pre-flashing settings can be selected from the third level menu
→
and/or
To modify the operating mode of the LP output, refer to the selection
→
.
The control panel has a slot for plug-in command and safety cards.
The action of the control card can be defined by selecting
When using slot-in radio boards, remove the RDX module. The display
will show
WARNING: the plug-in board must be inserted and removed with the
power supply disconnected.
Description
Insert the SOFA1-SOFA2 or GOPAVRS device in the slot
for plug-in boards AUX1 or AUX2.
If the test fails, an alarm message appears on the
display.
When selecting
→
contact of the safety device to terminals 1-6 on the con-
trol panel (in series with the photocell output contact,
if installed).
When selecting
→
contact of the safety device to terminals 1-8 on the con-
trol panel (in series with the photocell output contact,
if installed).
When selecting
→
contact of the safety device to terminals 1-6-8 on the
control panel (in series with the photocell output con-
tact, if installed).
If
→
,
and
Description
→
.
.
21
→
, connect the output
→
, connect the output
→
, connect the output
cannot be
or
.
→
.
EN