TROUBLE SHOOTING GUIDE

PROBLEM
Engine will
not start (see
Engine Manual
for further
engine
troubleshoot-
ing)
No or low
pressure
(initial use)
AWSC = Authorized Warranty Service Center
CAUSE
u f
N
o
. l e
Pressure builds up after two
pulls on the recoil starter or
after initial use.
Choke lever in the "No Choke"
position.
Spark plug wire not attached.
Engine switch in OFF
position.
Choke lever in the "Choke"
position on a "hot" engine
or an engine that has been
exposed to thermal heat for a
long period of time.
Spray wand not in high pres-
sure.
Low water supply.
Leak at high pressure hose
fitting.
Nozzle obstructed.
Water filter screen clogged.
CORRECTION
A
d
d
F
u
. l e
Squeeze gun trigger to relieve
pressure.
Move choke to the "Choke"
position.
Attach spark plug wire.
Place engine switch in ON posi-
tion.
Move choke to the "No Choke"
position.
See How to Use Spray Wand
instructions in the Operation
Section.
Water supply must be at least
5 GPM @ 20 psi.
Repair leak. Apply sealant tape
if necessary.
See Nozzle Cleaning instruc-
tions in the Maintenance sec-
tion.
Remove and clean filter.
33