Idiomas disponibles

Menu Map (cont.)

Main Level
Protocol Setup
Artnet Setup
Test Setup
Reset Setup
Information
* - The highest value to which the DMX address can be set is determined by the DMX
** - In Art-Net™ modes, the beginning of the IP address is set by the Net setting, to either:
NEXT NXT-1 User Manual Rev. 6
Programming Levels
Only DMX
Only ArtNet
ArtNet+DMX
KlingNet+DMX
IP Mode
Net
Subnet
Universe
Start Channel
Auto Test
Manual Test
Auto Reset
IP Address
Device ID
Temperature
Fixture Time
Software Version
CPU-B Error
CPU-C Error
Pan Sensor Error
Reset States
Pan Encode Error
Tilt Sensor Error
Tilt Encode Error
Temp Sensor Error
personality. For 9-channel mode: 504; for 10-channel mode: 503, 13-channel mode: 500;
23-channel mode: 490; 81-channel mode: 432; 106-channel mode: 407; and
119-channel mode: 394.
2, for Net setting 0,
or
10, for Net setting 1.
<Static>
< DHCP >
<Manual>
x**.xxx.xxx.xxx
0–127
0–15
0–15
1–512
Pan
Pan Fine
Tilt
Tilt Fine
P/T Speed
Dimmer
0–255
Shutter
Red
Green
Blue
White
x.xxx.xxx.xxx
xxxxxxxxx
XX
0–9999
CPU-A xxx
CPU-B xxx
CPU-C xxx
No
No
No
No
No
No
No
Description
Operating protocol
Static IP mode
DHCP IP mode
Manual IP mode
Art-Net™ net address
Art-Net™ subnet address
Art-Net™ universe
DMX start address
Runs auto test
Test pan movement
Test pan fine movement
Test tilt movement
Test tilt fine movement
Test pan/tilt speed
Test dimmer
Test shutter
Test red color
Test green color
Test blue color
Test white color
Restarts the product
Displays current IP address
Displays device ID
Displays current product temperature
Displays number of hours the product has
been powered
Current software versions
Displays Yes to any one of these items if the
Auto Reset found errors.
Operation