Activates or deactivates the push in closing function. Only with logic SLD:ON
On: The last second of the manoeuvre in closing phase is carried out at normal speed (disa-
BB
bling slowing) to favour a better hook of the electric lock.
Off: Function disabled.
Enables or disables the second radio channel on terminals 29/30.
2ch
On: Exit 29/30 configured with function as second radio channel.
Off: Exit 29/30 takes on function of service light (see parameter TLS).
Enables or disables checking of photocells on PHOT input, active both in closing and in
opening.
TST1
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See
Fig.3 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables checking of photocells on PHOT inputs, active only in closing.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded. See
TST2
Fig.3 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables motors check.
TSTm
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
Off: Check disabled.
(Enables or disables remote radiotransmitters learning, as indicated in the paragraph "Remote
transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
2Ch
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the pedestrian opening function
(see parameter TPED).
ped
Press the key of the transmitter to assign to this function.
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to erase from the memory.
CLR
If the code is valid, it is erased and the message OK is displayed
If the code is not valid or not present in memory, the message Err is displayed
Completely erases memory of the receiver. Confirmation of the operation is requested.
RTR
By selecting this function the receiver goes into waiting (Push) for a new PGM pressure to confirm the operation.
At end of erasing the OK message is displayed
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>>
<PG> 3456: made 123.456 cycles.
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of cycles of
manoeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message PROG.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the opening or clos-
ing operation.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The
transmitters are not erased from the receiver nor is the access password.
All the logics and all the parameters are brought back to default values, it is therefore necessary to repeat the autoset procedure.
18
RADIO (RAD)
CYCLES NUMBER (Nman)
MAINTENANCE CYCLES (maci)
RESET (RES)
FUNZIONE
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)