1) AUTOSET FUNCTION
IMPORTANT: The control unit is equipped with the Autoset function to automatically set the main functioning values based on the type of installation.
The AUTOSET function must be repeated at every function parameter change or upon change of automation conditions. See the AUTO menu for
further information.

2) TECHNICAL DATA

Contol unit supply
Power supply
Output supply
Maximum motor current
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported

3) WIRE DIAGRAM

Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
7-8
Lock
SCA/
9-10
PHOTO TEST
11-12
24 Vac/dc
13
COM/ENC+
14
SWO1/ENC1
15
SWC1
16
SWO2/ENC2
17
SWC2
18
PHOT
19
PHOT C
20
STOP
21
OPEN
22
CLOSE
23
PED
24
Step-by-Step
25
COM/ENC+
26
ENC-
SENSITIVE
27-28
EDGE
(DAS)
14
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1/2 motor 24Vdc
5+5 A
24Vdc 500mA max.
IP55
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64
Description
Connection, motor 1: 24VDC 5A max
Connection, motor 2: 24VDC 5A max
Connection, flashing light 24VDC 15W max.
Output, 12Vdc/10W power supply for electric lock (7:0V, 8:+12V)
Contact free from N.O. Voltage, may be configured as open gate indicator or photocell test.
For use as "Open gate indicator" the TEST1 and TEST2 logics must be OFF
For use as photocell test it is sufficient to activate one or both TEST logics and connect the
photocells as indicated in Fig.3.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board is installed, the output (without mains power connected)
has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switch and all the command inlets or encoder power supply.
Motor 1 OPEN limit switch input (N.C. contact) or Motor 1 Encoder connection.
Motor 1 CLOSE limit switch input, (N.C. Contact)
Motor 2 OPEN limit switch input, (N.C. Contact) or Motor 2 Encoder connection.
Motor 2 CLOSE limit switch input, (N.C. Contact)
Input, photocell activated in both opening and closing phases
Input, photocell activated in closing phase only (Normally closed contact)
Input, STOP push-button (Normally closed contact)
Input, OPEN push-button (Normally open contact).
It is possible to connect a timer for opening in time slots.
Input, CLOSE push-button (Normally open contact)
Pedestrian button input (N.O. Contact), controls the motor 1 opening, see TPED parameter.
Input, step-by-step push button (Normally open contact)
Common for Limit switch and all the command inputs or encoder power supply.
Input for GND Encoder connection (see Fig.2).
Input, sensitive edge contact
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.