Preface; Introduction; Identification Of The Product; General Description - PLYMOVENT Multidust bank BM-2 Instrucciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

pREFacE

using this manual
This manual is intended to be used as a work of reference for
professional, well-trained and authorized users to be able to
safely install, use, maintain and repair the product
mentioned on the cover of this document.
pictograms and symbols
The following pictograms and symbols are used in this
manual:
attENtiON
A remark with additional information for the user.
A remark brings possible problems to the user's
attention.
cautiON!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop
or the environment.
waRNiNg!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
waRNiNg!
Denotes risk of electric shock.
waRNiNg!
Fire hazard! Important warning to prevent fire.
Use protection gloves, if not carried out with the
necessary caution, may cause serious personal
injury.
Use breathing protection, if not carried out with
the necessary caution, may cause serious personal
injury.
text indicators
Listings indicated by "-" (hyphen) concern enumerations.
Listings indicated by "•" (bullet point) describe steps to
perform.
1

iNtRODuctiON

1.1

Identification of the product

The identification plate contains, among other things, the
following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2

General description

The MDB W2/W3 is a self-cleaning filter unit.
The extraction fan setting can be freely selected within the
max. and min. permissible volumetric flow of the filter. The
filter can be equipped either with a control panel with a filter
controller and integral frequency converter (SCP series) or
simply with a filter controller (Cont. B and C series).
The fan draws air laden with suspended particles through the
bank of filters. If the pressure upstream of the filters reaches
a certain value, the integral self-cleaning mechanism is
triggered which initiates the cleaning cycle to clean the dust
from the filter cartridges by pulses of compressed air. This
displaces the particles that have collected on the filter
cartridges so that the particles fall into the dust container in
the base of the MultiDust Bank.
0000100513/011212/0 MDB
1.3

Service and technical support

For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing
to help you.
Make sure you have the following specifications at hand:
- product name
- serial number
These data can be found on the identification plate.
1.4

Technical specifications

user manual MDb w2 and w3
Type
Welding
fume class
according to
ISO 15012-1
MDB-6-W2
W2
MDB-6-W3
W3
MDB-8-H-W2
W2
MDB-8-V-W2
MDB-8-H-W3
W3
MDB-8-V-W3
MDB-10-V-W2
W2
MDB-10-V-W3
W3
MDB-12-W2
W2
MDB-12-V-W2
MDB-12-H-W2
MDB-12-W3
W3
MDB-12-V-W3
MDB-12-H-W3
MDB-16-W2
W2
MDB-16-V-W2
MDB-16-H-W2
MDB-16-W3
W3
MDB-16-V-W3
MDB-16-H-W3
MDB-20-W2
W2
MDB-20-W3
W3
MDB-24-V-W2
W2
MDB-24-H-W2
MDB-24-V-W3
W3
MDB-24-H-W3
MDB-32-V-W2
W2
MDB-32-H-W2
MDB-32-V-W3
W3
MDB-32-H-W3
MDB-36-W2
W2
MDB-36-W3
W3
Number
Filter surface
of filter
cartridges
m
ft
2
2
6
90
969
6
60
646
8
120
1292
8
80
861
10
150
1615
10
100
1076
12
160
1722
12
120
1292
16
240
2583
16
160
1722
20
300
3229
20
200
2153
24
360
3875
24
240
2583
32
480
5167
32
320
3445
36
540
5813
36
360
3875
3