Step 4: Installing Anti-Tip
Device
For 30" and 36" ranges, an anti-tip device must be installed
as per these instructions.
WARNING - RANGE TIPPING
HAZARD
•
All ranges can tip and injury can result. To
prevent accidental tipping of the range,
attach it to the floor, wall or cabinet by
installing the Anti-Tip Device supplied.
•
A risk of tip-over may exist if the appliance
is not installed in accordance with these
instructions.
•
If the range is pulled away from the wall for
cleaning, service or any other reason,
ensure that the Anti-Tip Device is properly
reengaged when the range is pushed back
against the wall. In the event of abnormal
usage (such as a person standing, sitting,
or leaning on an open door), failure to take
this precaution can result in tipping of the
range. Personal injury might result from
spilled hot liquids or from the range itself.
WARNING - ELECRICAL SHOCK
HAZARD
•
Use extreme caution when drilling holes
into the wall or floor. There may be
concealed electrical wires located behind
the wall or under the floor.
•
Identify the electrical circuits that could be
affected by the installation of the Anti-Tip
Device, then turn off power to these
circuits.
•
Failure to follow these instructions may
result in electrical shock or other personal
injury.
WARNING:
-
All Ranges can tip.
-
Injury to Persons could result.
-
Install Anti-Tip Device packaged
with range.
-
Verify that the anti-tip device is
engaged.
-
See Installation Instructions.
English 10
ATTENTION - PROPERTY DAMAGE
•
Contact a qualified installer or contractor to determine
the proper method for drilling holes through the wall or
floor material (such as ceramic tile, hardwood, etc.)
•
Do not slide the range across an unprotected floor.
•
Failure to follow these instructions may result in
damage to wall or floor coverings.
Tools Needed for Installation of Anti-Tip Device:
•
Screwdriver, Phillips
•
Drill, electric or hand
•
Measuring tape or ruler
•
1/8" drill bit (wood or metal wall or floor)
•
Hammer
•
Pencil or other marker
•
3/16" carbide-tipped masonry drill bit (concrete or
concrete block wall or floor)
•
3/16" anchors, drywall or concrete, 4 each (not
required if mounting bracket is being attached to solid
wood or metal)
For 30" and 36" Dual Fuel Ranges (Figure 6 and
Figure 7)
Thermador
Qty
Service Part
No.
415078
4
647936
1
Important Installation Information:
•
The anti-tip bracket may be attached to a solid wood
cabinet having a minimum wall thickness of 3/4".
•
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
•
In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood or metal.
•
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
Description
Screw, Phillips, #10 x 1-1/2"
Anti-Tip Bracket, Floor-
Mounted