Step 6: Electrical Requirements, Connection & Grounding - Thermador PRO-HARMONY PRD30 Manual De Instalación

Todo tipo de gas
Ocultar thumbs Ver también para PRO-HARMONY PRD30:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 8: Location of Gas Supply Inlet Connection
MODEL
TYPE
30"
36"
48"
A neutral supply wire must be provided from the power
source (breaker/fuse panel) because critical range
components, including the surface burner spark
reignition module, require 120 VAC to operate safely
and properly.
on 30" and 36" Ranges
Chart B: Electrical Supply Circuit Requirements
VOLTAGE
240/208 VAC
240/208 VAC
240/208 VAC
Figure 9: Location of Gas Supply Inlet Connection on 48"
Step 6: Electrical
Requirements, Connection &
Grounding
Prior to servicing appliance, always disconnect
appliance electrical supply cord, if so equipped, from
wall receptacle. If appliance is hard-wired to power
supply, disconnect power to unit by turning off the
proper circuit breaker or disconnecting the proper fuse.
Lock service panel to prevent power from being turned
ON accidentally.
Dual Fuel range models can be connected or hardwired to
the power supply as described on page 14.
CIRCUIT
FREQUENCY
RATING
35 Amps
35 Amps
50 Amps
WARNING
An improper 120/ 240 VAC power supply will
cause malfunction, damage to this appliance,
and possibly create a condition of shock hazard.
A
PHASE
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
English 13
Ranges