Boubleshooting - LG DLEXOOOITM Guia Del Usario E Instrucciones De Instalacion

Secadora con vapor
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BOUBLESHOOTING
BEFORE CALLING FOR SERVICE
(cont.)
Steam doesn't
• Water level error.
• Unplug dryer and call for service.
generate
but no error
code is shown.
Garments
still
• Too many or too different
• Small loads of 1 to 5 items work best.
wrinkled
after
types of garments in dryer.
• Load fewer garments. Load similar-type garments.
STEAM FRESH
TM.
There are no creases
• The function of this cycle
• Use an iron to make creases.
left on garment after
is to remove wrinkles from
STEAM FRESH
TM.
fabric.
Garments have
• This is normal.
• Depends on individual moisture level in skin.
static after REDUCE
STATIC.
Garments are too
• Correct drying options not
• Select load weight manually before starting
damp or too dry after
selected.
REDUCE STATIC option.
REDUCE STATIC.
Garments are not
• This is normal.
• Depends on the amount or type of garments.
uniformly
damp after
EASY IRON.
Water drips from door
• This is normal.
• This is steam condensation
on door surface.
during EASY IRON.
Steam is not visible
• This is normal.
• Steam vapor is difficult to see when the door is
during Steam Cycle.
closed.
Drum does not turn
• This is normal.
• The drum is turned off so that the steam vapor
during Steam Cycle.
remains in the drum.
Cannot see steam
• This is normal.
• Steam is released at different stages of the cycle
vapor at the
for each option.
beginning
of cycle.
The display shows
• MORE TIME button pressed.
• Pressing the MORE TIME button several times will
BULKY LOAD.
set the cycle for a large load such as a comforter.
Odors remain in
• STEAM FRESH 'Mdid not
• Fabrics containing strong odors should be
clothing
after
remove odor completely,
washed in a normal cycle.
STEAM FRESH
TM.
• Install a shorter or straighter duct run. See the
Installation Instructions.
2 bars are displayed
in FLOW CHECK
indicator
4 bars are displayed
in FLOW CHECK
indicator
• Ductwork is slightly too
long or has too many
turns/restrictions.
• Partial blockage of the
ductwork due to lint buildup.
• Ductwork is too long or has
too many turns/restrictions.
• Significant blockage of the
ductwork due to lint buildup
or debris.
• Ductwork should be checked/cleaned
soon.
Dryer can be used in this condition, but drying
times may be longer.
Install a shorter or straighter duct run. See the
Installation Instructions.
Ductwork should be checked/cleaned
immediately
to remove lint buildup and other blockages. Dryer
can be used, but performance
and efficiency will be
greatly reduced.

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Dlgx0002tm

Tabla de contenido