Connecting an external control unit
When connecting the external control unit to the MAKE terminal, you can operate the following functions through the
MAKE terminal;
• Turn on or off the Monitor.
Preparation: The POWER switch on the rear must be set to "| (on)" (so that the Monitor is in standby mode).
• Select the input.
Preparation: "REMOTE SWITCH" should be set correctly to select your desired input (see page 27).
Notes:
• There is no remote control on/off switch. When a plug is inserted to the MAKE terminal, remote control through the
external control unit is automatically activated.
• When the other REMOTE terminals are used at the same time, transmitted commands through the MAKE terminal have
priority over those through the other terminals.
• MAKE terminal
Pin number
6
5
1
3
4
2
2
1
3
4
5
6
IMPORTANT:
External control unit is not commercially available in the market. When you need it, consult your dealer.
Connecting the Cooling Fan Unit (not supplied)
When installing this Monitor vertically, it is required to attach the Cooling Fan Unit.
Note: If you install the Monitor in such a way not instructed in this manual (for example, installing it diagonally), the
Cooling Fan Unit may not be able to cool down the internal heat enough to make the Monitor operate; therefore,
reinstallation or another method for cooling will be required.
• For more detailed connection, refer to the manual supplied with the Cooling Fan Unit.
Cooling Fan Unit:
TS-C01FANG(Option)
Signal name
Signals
GND
transmitted
GND
=
SW2
○
○
○
○
=
SW1
○
○
○
○
=
SW DET
○
○
○
○
GND
* Input A and Input B will be determined by the "REMOTE
• External control unit
TTL level
H: Power Off
L: Power On
H: Input A*
L: Input B*
H: Not connected
L: Connected
SWITCH" setting.
IMPORTANT:
When installing the Monitor
vertically, consult your dealer.
13